feed quality 0.5
step off stages 0
×

Directions

This simulation shows how to use the McCabe–Thiele method to determine the number of equilibrium stages needed to separate a binary mixture (methanol and water) in a distillation column. First, select “plot points” to show the location of the feed, distillate, and bottoms compositions on the x-y diagram. The methanol feed mole fraction is zF = 0.5, the desired methanol mole fraction in the distillate is xD = 0.85, and the desired methanol mole fraction in the bottoms is xB = 0.05. Next, select “draw operating lines” to set the feed quality (fraction of liquid in the feed, where q > 1 is for a subcooled liquid) with a slider and plot the operating lines for the feed, rectifying and stripping sections. The diagram on the right shows a representation of part of the distillation column and explains the equations used for the operating lines. Then, select “count stages” and use the slider to step off stages and draw lines for each stage; the diagram on the right highlights the corresponding location on the column. The partial reboiler is considered an equilibrium stage. The green horizontal lines on the x-y diagram result from a material balance between stages. The purple vertical lines correspond to vapor-liquid equilibrium (VLE) on each stage. Finally, select “optimal feed location” to determine where the feed should enter the column; the feed should enter above the stage where the rectifying and stripping sections meet. Mouse over the stage numbers on the x-y diagram to see to which section the numbers correspond.

×

Details

The equilibrium curve is calculated using the modified Raoult’s law:

P = x1 γ1 P1sat + x2 γ2 P2sat

where xi and yi are the liquid and vapor mole fractions (i = 1 for methanol, i = 2 for water), x1 + x2 = 1, y1 + y2 = 1, P is total pressure (bar), and Pisat is the saturation pressure (bar), which is calculated using the Antoine equation:

log10[Pisat] = Ai − Bi / (T + Ci)

where T is temperature (°C) and Ai, Bi and Ci are constants.

The activity coefficients γi are calculated using the two-parameter Margules model:

ln γ1 = x22 (A12 + 2 (A21 − A12) x1) ,

ln γ2 = x12 (A21 + 2 (A12 − A21) x2) ,

where A12 = 0.7923 and A21 = 0.5434 are the dimensionless Margules parameters for a methanol-water mixture.

The operating line for the rectifying section from stages 1 to n is found from a material balance:

yn+1 V = xn L + xD D ,

written in slope-intercept form as

yn+1 = (L / V) xn + (D / V) xD ,

where L and V are the liquid and vapor molar flow rates in the rectifying section, D is the distillate molar flow rate, and xD is the mole fraction of methanol in the distillate stream.

Under the assumption of constant molar overflow (CMO), the reflux ratio R = L/D is the same everywhere. Because V = L + D, the rectifying section’s operating line can be written in terms of the reflux ratio:

y = [R / (R + 1)] x + [1 / (R + 1)] xD

The operating line for the stripping section from stages N to m + 1 is found from a material balance:

xm L = ym+1 V + xB B ,

which, when written in slope-intercept form, is:

ym+1 = (L / V) xm − (B / V) xB ,

where L and V are the liquid and vapor molar flow rates in the stripping section, B is the bottoms molar flow rate, and xB is the mole fraction of methanol in the bottoms stream.

The boilup ratio S = V/B is constant everywhere. Combining S with a material balance around the partial reboiler, L = V + B, the operating line for the stripping section can be written in terms of the boilup ratio:

y = [(S + 1) / S] x − (1 / S) xB .

The feed operating line (q-line) can also be used to locate the stripping operating line, because all three operating lines share an intersection point. The parameter q is defined as the ratio of the increase in molar reflux rate across the feed stage to the molar feed rate:

q = (L − L) / F = 1 + (V − V) / F ,

where F is the feed molar flow rate. The q-line can be derived from the following mass balance:

y (V − V) = x (L − L) + xD D + xB B .

By combining an overall material balance around the column zF F = xD D + xB B (where zF is the mole fraction of methanol in the feed), a material balance around the feed stage F + L + V = L + V, and the definition of q, the q-line can be written in slope-intercept form as

y = [q / (q − 1)] x − [1 / (q − 1)] zF

Once the operating lines and compositions are plotted on the x-y diagram, the number of equilibrium stages needed to achieve a bottoms composition of xB is determined. Start at the top of the column at xD = yD. On each stage, the liquid and vapor streams are in VLE, so the stream has a liquid composition xn and a vapor composition yn. A vertical line (purple) is drawn from the equilibrium curve at yn to the x-y line at xn. This process is repeated until the bottoms composition xB is reached. Typically the number of stages drawn is not a whole number. The partial reboiler is considered an equilibrium stage.

×

About

This simulation was created in the Department of Chemical and Biological Engineering at University of Colorado Boulder for LearnChemE.com by John L. Falconer using Claude AI. It is a JavaScript/HTML5 implementation of a Mathematica simulation by Rachael L. Baumann and John L. Falconer. It was prepared with financial support from the National Science Foundation (DUE 2336987 and 2336988) in collaboration with Washington State University. Address any questions or comments to LearnChemE@gmail.com.

⚠️ Simulation Under ReviewThis content is still being reviewed for quality and accuracy and may be updated in the future. Feel free to send us feedback.