A 5 mol% acetone/95 mole% air stream flows into a condenser at a rate of 1000 kmol/h. The acetone is recovered from air using a cryogenic process with temperatures between −100 °C and −20 °C. The liquid phase that exits the process is pure acetone. A 10 °C approach temperature is chosen, which allows the determination of the isothermal flash temperature from the user-set value of the coolant temperature. The simulation displays the flow rates and their mole fractions. At sufficiently low condenser temperatures, almost 100% of the acetone can be recovered.
The feed (component 1 = acetone, component 2 = air) is flashed at the drum temperature \(T\), which is set by a 10 °C approach to the coolant temperature \(\theta\):
The overall and acetone mole balances on the flash drum are
with feed rate \(F = 1000\ \text{kmol/h}\) and feed acetone fraction \(z = 0.05\). Here \(x\) and \(y\) are the acetone mole fractions in the liquid and vapor, \(L\) and \(V\) are the liquid and vapor molar flow rates.
Vapor–liquid equilibrium uses a modified Raoult's law with Wilson activity coefficients \(\gamma_i\):
with total pressure \(P = 101.325\ \text{kPa}\).
The saturation pressures (kPa) are given by the extended (DIPPR) Antoine form:
The Wilson model gives
where \(x_1 = x\), \(x_2 = 1 - x\), and \(R = 1.987\ \text{cal/(mol·K)}\). The four VLE and balance equations are solved for \(x,\,y,\,L,\,V\) at each temperature.
Antoine (DIPPR) coefficients
| \(A\) | \(B\) | \(C\) | \(D\) | \(E\) | \(F\) | |
|---|---|---|---|---|---|---|
| acetone (1) | 71.13031 | −5952 | 0 | −8.53128 | 7.82393×10−6 | 2 |
| air (2) | 21.662 | −692.39 | 0 | −0.39208 | 4.7574×10−3 | 1 |
Wilson parameters (cal/mol): \(\lambda_{12} = 906.5\), \(\lambda_{21} = -1.805\), \(b_{12} = -0.002\), \(b_{21} = 1.916\), \(V_1 = 7.44767\), \(V_2 = 3.29136\).
Symbols
| \(A_i\)–\(F_i\) | Antoine (DIPPR) coefficients for component \(i\) |
| \(b_{12},\,b_{21}\) | temperature coefficients in the Wilson parameters (cal/(mol·K)) |
| \(F\) | feed molar flow rate (kmol/h) |
| \(L\) | liquid molar flow rate (kmol/h) |
| \(P\) | total pressure (kPa) |
| \(P_i^{\,\text{sat}}\) | saturation pressure of component \(i\) (kPa) |
| \(R\) | ideal gas constant (cal/(mol·K)) |
| \(T\) | flash drum temperature (K) |
| \(V\) | vapor molar flow rate (kmol/h) |
| \(V_1,\,V_2\) | Wilson molar-volume parameters of acetone and air |
| \(x\) | acetone mole fraction in liquid |
| \(x_1,\,x_2\) | liquid mole fractions of acetone and air |
| \(y\) | acetone mole fraction in vapor |
| \(z\) | acetone mole fraction in feed |
| \(\gamma_i\) | activity coefficient of component \(i\) |
| \(\theta\) | coolant temperature (°C) |
| \(\lambda_{12},\,\lambda_{21}\) | Wilson interaction energies (cal/mol) |
| \(\Lambda_{12},\,\Lambda_{21}\) | Wilson binary parameters |
This simulation was created in the Department of Chemical and Biological Engineering at University of Colorado Boulder for LearnChemE.com by John L. Falconer using Claude AI. It is a JavaScript/HTML5 implementation of a Mathematica simulation by Housam Binous and Ahmed Bellagi. It was prepared with financial support from the National Science Foundation (DUE 2336987 and 2336988). Address any questions or comments to LearnChemE@gmail.com.